Re: signal(SIGFPE,SIG_IGN) causes endless loop

Paul Slootman (paul@waubel.ahwau.ahold.nl)
Tue, 23 Apr 1996 13:40:28 +0000 (ZOM)


albert@ccs.neu.edu wrote:

>OK, what about x86 OSs? This could affect iBCS a bit.

SVR4 x86 (Siemens Nixdorf Sinix 5.41B): endless loop

Excerpt from truss:
signal(SIGFPE, SIG_IGN) = SIG_DFL
Incurred fault #8, FLTIZDIV %pc = 0x08048446
siginfo: SIGFPE FPE_INTDIV addr=0x00000000
Received signal #8, SIGFPE [ignored]
siginfo: SIGFPE FPE_INTDIV addr=0x00000000
Incurred fault #8, FLTIZDIV %pc = 0x08048446
siginfo: SIGFPE FPE_INTDIV addr=0x00000000
Received signal #8, SIGFPE [ignored]
siginfo: SIGFPE FPE_INTDIV addr=0x00000000
[repeated ad nauseam]

Paul Slootman

--
Murphy Software, Enschede, The Netherlands          There is no such thing
work: paul@wau.mis.ah.nl / paul@murphy.nl                as a coincidence.
home: paul@wurtel.hobby.nl