Re: [PATCH V4 2/2] regulator: mt6323: Add support for MT6323 regulator

From: menghui lin
Date: Wed Feb 03 2016 - 21:42:52 EST


On Wed, 2016-02-03 at 12:29 +0000, Mark Brown wrote:
> On Wed, Feb 03, 2016 at 01:39:02PM +0800, menghui lin wrote:
> > On Tue, 2016-02-02 at 19:38 +0000, Mark Brown wrote:
>
> > > How does the driver know if it needs to change the mode (ie, how can it
> > > tell if the current mode is inadequate) and surely if we can only change
> > > in one direction this isn't terribly useful?
>
> > I think the datasheet of buck/ldo could provide information about power
> > capability of each mode. The driver should adjust regulator mode per its
> > device's power requirement.
>
> That's of no help for a consumer driver which doesn't know what
> regulator is supplying it.
>
> > case 1:
>
> > We have a USB typeC micro-controller, which has two modes - standby and
> > normal. It requires 1.8V and 3.3V to operate (both powers are always
> > on). The device stays in standby mode when there is no cable in. When
> > cable in, we got an interrupt and change device into normal mode.
>
> > The standby mode power consumption is quite small, so we would like the
> > change mode of regulator into STANDBY to save more power. And we change
> > into NORMAL when we receive cable-in interrupt.
>
> This seems like something that we ought to be doing via runtime PM
> anyway which should be going through the suspend mode bindings, though
> that would need some plumbing in.
>
> > case 2:
>
> > About buck regulator for CPU, it usually provides PWM mode, PWM/PFM Auto
> > mode, PFM mode. I think it could map to FAST, NORMAL, IDLE mode
> > respectively. Most of time we would use just normal mode. However, we
> > would change regulator into PWM mode time to time to test buck output
> > performance on the tested board.
>
> That's a test use that doesn't seem a good fit for upstream at all.

Hi Mark,

Thanks for your response.
It seems more work is required for dynamic mode switch.
For MT6323 regulator patch, we would remove mode-switch related code for
now to provide basic regulator support first.