Re: [PATCH] x86/mrst: move sfi timer irqs after gsi_top

From: Feng Tang
Date: Wed Apr 06 2011 - 21:27:03 EST


Hi Jacob,

The mrst vrtc driver has the similar irq number problem in 2.6.39-rc2,
how about the following patch to solve it in ioapic code.

Also I saw NR_IRQS_LEGACY are used in several other places of io_apic code,
it may has some potential issue for mrst which I'm not sure.

Thanks,