Re: [PATCH v4 8/8] dt-bindings: stm32: use reference manual names for ETR and STM bus clocks (ATTN: Krzysztof)
From: Brian Masney
Date: Thu Nov 19 2026 - 10:04:03 EST
Hi Krzysztof,
On Wed, Nov 11, 2026 at 05:32:04PM -0500, Brian Masney wrote:
> > The bus clocks of the STM and of the ETR are identified by CK_BUS_STM500,
> > CK_SCMI_STM500 and CK_SCMI_ETR. Now that their kernel clocks are
> > described as CK_KER_STM and CK_KER_ETR, and as the RCC bus clock of the
> > ETR is already CK_BUS_ETR, these names are confusing. They also differ
> > from the reference manual and from the STM32MP21 binding, which uses
> > CK_BUS_STM, CK_SCMI_BUS_ETR and CK_SCMI_BUS_STM for the same clocks.
> >
> > Use CK_BUS_STM, CK_SCMI_BUS_ETR and CK_SCMI_BUS_STM, with unchanged
> > values, and keep the old names as deprecated aliases so that the
> > existing users are not affected.
> >
> > No functional change.
> >
> > Signed-off-by: Gabriel Fernandez <gabriel.fernandez@xxxxxxxxxxx>
>
> You acked the other dt-binding patches in this series. Can you take a
> look at this patch as well?
>
> The other clock patches look good to me.
Gentle ping to take a look at the last patch in this series please.
Thanks,
Brian