[PATCH] iio: adc: ti-tsc2046: use us_to_ktime() where appropriate

From: Xichao Zhao
Date: Wed Aug 13 2025 - 03:56:58 EST


The scan_interval_us and time_per_scan_us are more suitable for
using the us_to_ktime(). This can make the code more concise and
enhance readability. Therefore, replace ns_to_ktime() with us_to_ktime().

Signed-off-by: Xichao Zhao <zhao.xichao@xxxxxxxx>
---
drivers/iio/adc/ti-tsc2046.c | 6 ++----
1 file changed, 2 insertions(+), 4 deletions(-)

diff --git a/drivers/iio/adc/ti-tsc2046.c b/drivers/iio/adc/ti-tsc2046.c
index 74471f08662e..8eb717b11cff 100644
--- a/drivers/iio/adc/ti-tsc2046.c
+++ b/drivers/iio/adc/ti-tsc2046.c
@@ -535,8 +535,7 @@ static enum hrtimer_restart tsc2046_adc_timer(struct hrtimer *hrtimer)
if (priv->poll_cnt < TI_TSC2046_POLL_CNT) {
priv->poll_cnt++;
hrtimer_start(&priv->trig_timer,
- ns_to_ktime(priv->scan_interval_us *
- NSEC_PER_USEC),
+ us_to_ktime(priv->scan_interval_us),
HRTIMER_MODE_REL_SOFT);

if (priv->poll_cnt >= TI_TSC2046_MIN_POLL_CNT) {
@@ -605,8 +604,7 @@ static void tsc2046_adc_reenable_trigger(struct iio_trigger *trig)
* many samples. Reduce the sample rate for default (touchscreen) use
* case.
*/
- tim = ns_to_ktime((priv->scan_interval_us - priv->time_per_scan_us) *
- NSEC_PER_USEC);
+ tim = us_to_ktime(priv->scan_interval_us - priv->time_per_scan_us);
hrtimer_start(&priv->trig_timer, tim, HRTIMER_MODE_REL_SOFT);
}

--
2.34.1