Re: [PATCH net v3 2/4] dt-bindings: ethernet-phy: add MII-Lite phy interface type
From: Maxime Chevallier
Date: Mon Jun 30 2025 - 09:16:38 EST
On Mon, 30 Jun 2025 13:30:31 +0200
Kamil Horák - 2N <kamilh@xxxxxxxx> wrote:
> Some Broadcom PHYs are capable to operate in simplified MII mode,
> without TXER, RXER, CRS and COL signals as defined for the MII.
> The MII-Lite mode can be used on most Ethernet controllers with full
> MII interface by just leaving the input signals (RXER, CRS, COL)
> inactive. The absence of COL signal makes half-duplex link modes
> impossible but does not interfere with BroadR-Reach link modes on
> Broadcom PHYs, because they are all full-duplex only.
>
> Add new interface type "mii-lite" to phy-connection-type enum.
>
> Signed-off-by: Kamil Horák - 2N <kamilh@xxxxxxxx>
Reviewed-by: Maxime Chevallier <maxime.chevallier@xxxxxxxxxxx>
Maxime