Re: [PATCH net-next v2 2/3] net: phy: dp83tg720: remove redundant 600ms post-reset delay
From: Andrew Lunn
Date: Thu Jun 12 2025 - 11:39:24 EST
On Thu, Jun 12, 2025 at 12:41:56PM +0200, Oleksij Rempel wrote:
> From: David Jander <david@xxxxxxxxxxx>
>
> Now that dp83tg720_soft_reset() introduces role-specific delays to avoid
> reset synchronization deadlocks, the fixed 600ms post-reset delay in
> dp83tg720_read_status() is no longer needed.
>
> The new logic provides both the required MDC timing and link stabilization,
> making the old empirical delay redundant and unnecessarily long.
>
> Co-developed-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
> Signed-off-by: David Jander <david@xxxxxxxxxxx>
> Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
Andrew