From: Robert Marko <robimarko@xxxxxxxxx>
Aquantia PHY-s require firmware to be loaded before they start operating.
It can be automatically loaded in case when there is a SPI-NOR connected
to Aquantia PHY-s or can be loaded from the host via MDIO.
This patch adds support for loading the firmware via MDIO as in most cases
there is no SPI-NOR being used to save on cost.
Firmware loading code itself is ported from mainline U-boot with cleanups.
The firmware has mixed values both in big and little endian.
PHY core itself is big-endian but it expects values to be in little-endian.
The firmware is little-endian but CRC-16 value for it is stored at the end
of firmware in big-endian.
It seems the PHY does the conversion internally from firmware that is
little-endian to the PHY that is big-endian on using the mailbox
but mailbox returns a big-endian CRC-16 to verify the written data
integrity.
Co-developed-by: Christian Marangi <ansuelsmth@xxxxxxxxx>
Signed-off-by: Robert Marko <robimarko@xxxxxxxxx>
Signed-off-by: Christian Marangi <ansuelsmth@xxxxxxxxx>
---
+static int aqr_firmware_load_fs(struct phy_device *phydev)
+{
+ struct device *dev = &phydev->mdio.dev;
+ const struct firmware *fw;
+ const char *fw_name;
+ int ret;
+
+ ret = of_property_read_string(dev->of_node, "firmware-name",
+ &fw_name);
+ if (ret)
+ return ret;
+
+ ret = request_firmware(&fw, fw_name, dev);
+ if (ret) {
+ phydev_err(phydev, "failed to find FW file %s (%d)\n",
+ fw_name, ret);
+ goto exit;
+ }
+
+ ret = aqr_fw_boot(phydev, fw->data, fw->size, AQR_FW_SRC_FS);
+ if (ret)
+ phydev_err(phydev, "firmware loading failed: %d\n", ret);
+
+exit:
+ release_firmware(fw);
+
+ return ret;
+}