[PATCH v2 5/8] dt-bindings: power: supply: max77658: Add ADI MAX77658 Battery

From: Zeynep Arslanbenzer
Date: Wed Mar 22 2023 - 01:58:49 EST


Add ADI MAX77658 power supply devicetree document.

Signed-off-by: Nurettin Bolucu <Nurettin.Bolucu@xxxxxxxxxx>
Signed-off-by: Zeynep Arslanbenzer <Zeynep.Arslanbenzer@xxxxxxxxxx>
---
.../power/supply/adi,max77658-battery.yaml | 58 +++++++++++++++++++
1 file changed, 58 insertions(+)
create mode 100644 Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml

diff --git a/Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml b/Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml
new file mode 100644
index 000000000000..0b696f7c4d1b
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/adi,max77658-battery.yaml
@@ -0,0 +1,58 @@
+# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/power/supply/adi,max77658-battery.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Battery for MAX77658 PMIC from ADI.
+
+maintainers:
+ - Nurettin Bolucu <Nurettin.Bolucu@xxxxxxxxxx>
+ - Zeynep Arslanbenzer <Zeynep.Arslanbenzer@xxxxxxxxxx>
+
+description: |
+ This module is part of the MAX77658 MFD device. For more details
+ see Documentation/devicetree/bindings/mfd/adi,max77658.yaml.
+
+ The fuel gauge is represented as a sub-node of the PMIC node on the device tree.
+
+properties:
+ compatible:
+ const:
+ adi,max77658-battery
+
+ reg:
+ maxItems: 1
+
+ adi,valrt-min-microvolt:
+ description: Minimum voltage value that triggers the alarm.
+
+ adi,valrt-max-microvolt:
+ description: Maximum voltage value that triggers the alarm.
+
+ adi,salrt-min-percent:
+ description: Minimum percentage of battery that triggers the alarm.
+
+ adi,salrt-max-percent:
+ description: Maximum percentage of battery that triggers the alarm.
+
+ adi,ialrt-min-microamp:
+ description: Minimum current value that triggers the alarm.
+
+ adi,ialrt-max-microamp:
+ description: Maximum current value that triggers the alarm.
+
+ monitored-battery:
+ description: >
+ phandle to a "simple-battery" compatible node.
+
+ This property must be a phandle to a node using the format described
+ in battery.yaml, with the following properties being required:
+ - alert-celsius
+
+required:
+ - compatible
+
+additionalProperties: false
+
+...
--
2.25.1