Re: [PATCH v2 4/5] docs: hwmon: Add documenttaion for acbel-crps PSU

From: Guenter Roeck
Date: Mon Mar 20 2023 - 16:32:54 EST


On Mon, Mar 20, 2023 at 10:40:18AM -0500, Lakshmi Yadlapati wrote:
> Add documentation changes for acbel-crps psu
>
> Signed-off-by: Lakshmi Yadlapati <lakshmiy@xxxxxxxxxx>
> ---
> Documentation/hwmon/acbel-crps.rst | 81 ++++++++++++++++++++++++++++++
> 1 file changed, 81 insertions(+)
> create mode 100644 Documentation/hwmon/acbel-crps.rst
>
> diff --git a/Documentation/hwmon/acbel-crps.rst b/Documentation/hwmon/acbel-crps.rst
> new file mode 100644
> index 000000000000..89a43fb88c8c
> --- /dev/null
> +++ b/Documentation/hwmon/acbel-crps.rst
> @@ -0,0 +1,81 @@
> +Kernel driver acbel-crps
> +=======================
> +
> +Supported chips:
> +
> + * ACBEL Common Redundant Power Supply.
> + Supported models: FSG032-00xG
> +
> +Author: Lakshmi Yadlapati <lakshmiy@xxxxxxxxxx>
> +
> +Description
> +-----------
> +
> +This driver supports ACBEL Common Redundant Power Supply. This driver
> +is a client to the core PMBus driver.

No, it supports the FSG032-00xG power supply. Neither the driver nor its
documentation should claim otherwise.

> +
> +Usage Notes
> +-----------
> +
> +This driver does not auto-detect devices. You will have to instantiate the
> +devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
> +details.
> +
> +Sysfs entries
> +-------------
> +
> +The following attributes are supported:
> +
> +======================= ======================================================
> +curr1_crit Critical maximum current.
> +curr1_crit_alarm Input current critical alarm.
> +curr1_input Measured output current.
> +curr1_label "iin"
> +curr1_max Maximum input current.
> +curr1_max_alarm Maximum input current high alarm.
> +curr1_rated_max Maximum rated input current.
> +curr2_crit Critical maximum current.
> +curr2_crit_alarm Output current critical alarm.
> +curr2_input Measured output current.
> +curr2_label "iout1"
> +curr2_max Maximum output current.
> +curr2_max_alarm Output current high alarm.
> +curr2_rated_max Maximum rated output current.
> +
> +
> +fan1_alarm Fan 1 warning.
> +fan1_fault Fan 1 fault.
> +fan1_input Fan 1 speed in RPM.
> +fan1_target Set fan speed reference.
> +
> +in1_alarm Input voltage under-voltage alarm.
> +in1_input Measured input voltage.
> +in1_label "vin"
> +in1_rated_max Maximum rated input voltage.
> +in1_rated_min Minimum rated input voltage.
> +in2_crit Critical maximum output voltage.
> +in2_crit_alarm Output voltage critical high alarm.
> +in2_input Measured output voltage.
> +in2_label "vout1"
> +in2_lcrit Critical minimum output voltage.
> +in2_lcrit_alarm Output voltage critical low alarm.
> +in2_rated_max Maximum rated output voltage.
> +in2_rated_min Minimum rated output voltage.
> +
> +power1_alarm Input fault or alarm.
> +power1_input Measured input power.
> +power1_label "pin"
> +power1_max Input power limit.
> +power1_rated_max Maximum rated input power.
> +power2_crit Critical output power limit.
> +power2_crit_alarm Output power crit alarm limit exceeded.
> +power2_input Measured output power.
> +power2_label "pout"
> +power2_max Output power limit.
> +power2_max_alarm Output power high alarm.
> +power2_rated_max Maximum rated output power.
> +
> +temp[1-3]_input Measured temperature.
> +temp[1-2]_max Maximum temperature.
> +temp[1-3]_rated_max Temperature high alarm.
> +======================= ======================================================
> --
> 2.37.2
>