RE: [PATCH] mmc: block: workaround long ioctl busy timeout

From: Christian Löhle
Date: Mon Feb 13 2023 - 05:34:54 EST


Any more comments regarding this patch?

-----Original Message-----
From: Christian Löhle
Sent: Montag, 16. Januar 2023 15:38
To: adrian.hunter@xxxxxxxxx; 'Avri Altman' <Avri.Altman@xxxxxxx>; linux-mmc@xxxxxxxxxxxxxxx; linux-kernel@xxxxxxxxxxxxxxx
Cc: ulf.hansson@xxxxxxxxxx
Subject: [PATCH] mmc: block: workaround long ioctl busy timeout

The ioctl interface allowed to set cmd_timeout_ms when polling for busy on R1B commands. This was often limited by the max hw timeout so work around it like for the sanitize command.

Signed-off-by: Christian Loehle <cloehle@xxxxxxxxxxxxxx>
---
drivers/mmc/core/block.c | 10 +++++++++-
1 file changed, 9 insertions(+), 1 deletion(-)

diff --git a/drivers/mmc/core/block.c b/drivers/mmc/core/block.c index 20da7ed43e6d..ba3bc9014179 100644
--- a/drivers/mmc/core/block.c
+++ b/drivers/mmc/core/block.c
@@ -472,6 +472,8 @@ static int __mmc_blk_ioctl_cmd(struct mmc_card *card, struct mmc_blk_data *md,
struct scatterlist sg;
int err;
unsigned int target_part;
+ unsigned int busy_timeout = MMC_BLK_TIMEOUT_MS;
+ int poll_prog = false;

if (!card || !md || !idata)
return -EINVAL;
@@ -493,6 +495,12 @@ static int __mmc_blk_ioctl_cmd(struct mmc_card *card, struct mmc_blk_data *md,
cmd.opcode = idata->ic.opcode;
cmd.arg = idata->ic.arg;
cmd.flags = idata->ic.flags;
+ /* R1B flag might be removed here to work around hw, so save it */
+ poll_prog = (idata->rpmb || (cmd.flags & MMC_RSP_R1B) == MMC_RSP_R1B);
+ busy_timeout = idata->ic.cmd_timeout_ms ? :
+ MMC_BLK_TIMEOUT_MS;
+ if (poll_prog)
+ mmc_prepare_busy_cmd(card->host, &cmd, busy_timeout);

if (idata->buf_bytes) {
data.sg = &sg;
@@ -596,7 +604,7 @@ static int __mmc_blk_ioctl_cmd(struct mmc_card *card, struct mmc_blk_data *md,
if (idata->ic.postsleep_min_us)
usleep_range(idata->ic.postsleep_min_us, idata->ic.postsleep_max_us);

- if (idata->rpmb || (cmd.flags & MMC_RSP_R1B) == MMC_RSP_R1B) {
+ if (poll_prog) {
/*
* Ensure RPMB/R1B command has completed by polling CMD13 "Send Status". Here we
* allow to override the default timeout value if a custom timeout is specified.
--
2.37.3


Hyperstone GmbH | Reichenaustr. 39a | 78467 Konstanz
Managing Director: Dr. Jan Peter Berns.
Commercial register of local courts: Freiburg HRB381782