Re: [PATCH 3/5] hwmon: (aquacomputer_d5next) Add temperature offset control for Aquaero

From: Aleksa Savic
Date: Sat Feb 11 2023 - 13:54:14 EST


On 2023-02-11 19:08:27 GMT+01:00, Guenter Roeck wrote:
>
> aquaero is already supported, and the checksum is so far generated
> and sent. Is it ignored ? Also, is it guaranteed that _all_ aquero devices
> don't need it ?

Reading its sensors is currently supported, not writing to it (before these
patches).

The checksum is ignored and not needed for either aquaero 5 (which Leonard has)
nor 6 (which I have).

>
> If it is not needed and ignored, does it really add value to selectively drop it ?

I think we can indeed remove that check.

Thanks,
Aleksa

>
> Either case, this change is not mentioned in the commit log, and it
> violates the "one logical change per patch" rule. Please split it into
> a separate patch and explain why the change is needed.
>
> Another change to separate is the introduction of ctrl_report_id
> and the secondary_ctrl_report variables, which is also done silently
> and not explained. That should also be a separate patch to simplify
> review.
>
> Thanks,
> Guenter