Re: [PATCH v3 1/2] drm/panel: boe-tv101wum-nl6: Remove extra delay
From: AngeloGioacchino Del Regno
Date: Tue Jan 31 2023 - 03:35:47 EST
Il 31/01/23 02:59, xinlei.lee@xxxxxxxxxxxx ha scritto:
From: Xinlei Lee <xinlei.lee@xxxxxxxxxxxx>
Reduce the delay after LCM reset by removing an extra delay in the
initialization commands array. The required delay of at least 6ms after
reset is guaranteed by boe_panel_prepare().
Signed-off-by: Xinlei Lee <xinlei.lee@xxxxxxxxxxxx>
Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>