+Kernel driver MAX20754
+======================
+
+Supported chips:
+
+ * Maxim MAX20754
+
+ Prefix: 'max20754'
+
+ Addresses scanned: -
+
+ Datasheet: https://datasheets.maximintegrated.com/en/ds/MAX20754.pdf
+ Application Note:
+
+Author: Atif Emre Ofluoglu <Atif.Ofluoglu@xxxxxxxxxx>
+
+
+Description
+-----------
+
+This driver supports MAX20754 Dual-Output, Configurable Multiphase
+Power-Supply Controller with PMBus Interface and Internal Buck Converter.
+
+The driver is a client driver to the core PMBus driver.
+Please see Documentation/hwmon/pmbus.rst for details on PMBus client drivers.
+
+
+Usage Notes
+-----------
+
+This driver does not auto-detect devices. You will have to instantiate the
+devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
+details.
+
+
+Platform data support
+---------------------
+
+The driver supports standard PMBus driver platform data.
+
+
+Sysfs entries
+-------------
+
+The following attributes are supported.
+
+=============================== ===============================================
+in1_input Measured voltage on Supply Voltage.
+in1_label "vin1"
+in1_alarm Input voltage under-voltage alarm
+
+in2_label "vout1"
+in2_input Measured voltage on RAIL1.
+in2_min Minimum output voltage.
+in2_max Maximum output voltage.
+in2_lcrit Critical minimum output voltage.
+in2_crit Critical maximum output voltage.
+in2_lcrit_alarm Output voltage critical low alarm.
+in2_crit_alarm Output voltage critical high alarm.
+in2_min_alarm Output voltage low alarm.
+in2_max_alarm Output voltage high alarm.
+in2_rated_max Maximum rated output voltage
+in2_rated_min Minimum rated output voltage
+
+in3_label "vout2"
+in3_input Measured voltage on RAIL2.
+in3_min Minimum output voltage.
+in3_max Maximum output voltage.
+in3_lcrit Critical minimum output voltage.
+in3_crit Critical maximum output voltage.
+in3_lcrit_alarm Output voltage critical low alarm.
+in3_crit_alarm Output voltage critical high alarm.
+in3_min_alarm Output voltage low alarm.
+in3_max_alarm Output voltage high alarm.
+in3_rated_max Maximum rated output voltage
+in3_rated_min Minimum rated output voltage
+
+curr1_input Measured output current on RAIL1.
+curr1_label "iout1"
+curr1_max Maximum output current.
+curr1_max_alarm Output current high alarm.
+curr1_crit Critical maximum current
+curr1_crit_alarm Current critical high alarm
+
+curr2_input Measured output current on RAIL2.
+curr2_label "iout2"
+curr2_max Maximum output current.
+curr2_max_alarm Output current high alarm.
+curr2_crit Critical maximum current
+curr2_crit_alarm Current critical high alarm
+
+temp1_input Measured Temperature value of Die Core
+temp1_crit Maximum Temperature value of Die Core
+temp1_crit_alarm Maximum Temperature Alarm of Die Core
+temp1_max Over Temperature Warning value of Die Core
+temp1_max_alarm Over Temperature Warning value of Die Core
+temp1_min Under Temperature value of Die Core
+temp1_min_alarm Under Temperature Alarm of Die Core
+
+temp1_input Measured Temperature value of Temperature Sense 1
+temp1_crit Maximum Temperature value of Temperature Sense 1
+temp1_crit_alarm Maximum Temperature Alarm of Temperature Sense 1
+temp1_max Over Temperature Warning value of Temperature Sense 1
+temp1_max_alarm Over Temperature Warning value of Temperature Sense 1
+temp1_min Under Temperature value of Temperature Sense 1
+temp1_min_alarm Under Temperature Alarm of Temperature Sense 1
+
+temp1_input Measured Temperature value of Temperature Sense 1
+temp1_crit Maximum Temperature value of Temperature Sense 1
+temp1_crit_alarm Maximum Temperature Alarm of Temperature Sense 1
+temp1_max Over Temperature Warning value ofTemperature Sense 1
+temp1_max_alarm Over Temperature Warning Temperature Sense 1
+temp1_min Under Temperature value of Temperature Sense 1
+temp1_min_alarm Under Temperature Alarm of Temperature Sense 1
+
+vout1_command Determine Voltage read format of RAIL1
+vout2_command Determine Voltage read format of RAIL2
+
+on_off_config Configures Power On/Off behavior.
+operation Configures Power Supply Operation Mode.