Re: [PATCH 02/12] can: kvaser_usb: Fix use of uninitialized completion

From: Jimmy Assarsson
Date: Sat May 28 2022 - 03:37:04 EST


On 5/16/22 15:47, Anssi Hannula wrote:
flush_comp is initialized when CMD_FLUSH_QUEUE is sent to the device and
completed when the device sends CMD_FLUSH_QUEUE_RESP.

This causes completion of uninitialized completion if the device sends
CMD_FLUSH_QUEUE_RESP before CMD_FLUSH_QUEUE is ever sent (e.g. as a
response to a flush by a previously bound driver, or a misbehaving
device).

Fix that by initializing flush_comp in kvaser_usb_init_one() like the
other completions.

This issue is only triggerable after RX URBs have been set up, i.e. the
interface has been opened at least once.

Fixes: aec5fb2268b7 ("can: kvaser_usb: Add support for Kvaser USB hydra family")
Signed-off-by: Anssi Hannula <anssi.hannula@xxxxxxxxxx>

Looks good to me.
Tested-by: Jimmy Assarsson <extja@xxxxxxxxxx>


---
drivers/net/can/usb/kvaser_usb/kvaser_usb_core.c | 1 +
drivers/net/can/usb/kvaser_usb/kvaser_usb_hydra.c | 2 +-
2 files changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/net/can/usb/kvaser_usb/kvaser_usb_core.c b/drivers/net/can/usb/kvaser_usb/kvaser_usb_core.c
index e67658b53d02..47bff40c36b6 100644
--- a/drivers/net/can/usb/kvaser_usb/kvaser_usb_core.c
+++ b/drivers/net/can/usb/kvaser_usb/kvaser_usb_core.c
@@ -673,6 +673,7 @@ static int kvaser_usb_init_one(struct kvaser_usb *dev,
init_usb_anchor(&priv->tx_submitted);
init_completion(&priv->start_comp);
init_completion(&priv->stop_comp);
+ init_completion(&priv->flush_comp);
priv->can.ctrlmode_supported = 0;
priv->dev = dev;
diff --git a/drivers/net/can/usb/kvaser_usb/kvaser_usb_hydra.c b/drivers/net/can/usb/kvaser_usb/kvaser_usb_hydra.c
index a26823c5b62a..4e90a4b7f95a 100644
--- a/drivers/net/can/usb/kvaser_usb/kvaser_usb_hydra.c
+++ b/drivers/net/can/usb/kvaser_usb/kvaser_usb_hydra.c
@@ -1910,7 +1910,7 @@ static int kvaser_usb_hydra_flush_queue(struct kvaser_usb_net_priv *priv)
{
int err;
- init_completion(&priv->flush_comp);
+ reinit_completion(&priv->flush_comp);
err = kvaser_usb_hydra_send_simple_cmd(priv->dev, CMD_FLUSH_QUEUE,
priv->channel);