[PATCH 01/21] staging: r8188eu: switch the led off during deinit
From: Martin Kaiser
Date: Sun Dec 26 2021 - 14:56:26 EST
When the driver is unloaded or when the system goes into standby mode,
DeInitLed871x is called to stop the led layer. In this case, we stop
the blinking worker but we do not switch the led off explicitly. On my
system, I can go into standby mode with the LED enabled.
Add a call to SwLedOff to fix this.
Cc: stable@xxxxxxxxxxxxxxx
Fixes: 15865124feed ("staging: r8188eu: introduce new core dir for RTL8188eu driver")
Signed-off-by: Martin Kaiser <martin@xxxxxxxxx>
---
drivers/staging/r8188eu/core/rtw_led.c | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/staging/r8188eu/core/rtw_led.c b/drivers/staging/r8188eu/core/rtw_led.c
index e1be1ba189cb..25fab7bce7dc 100644
--- a/drivers/staging/r8188eu/core/rtw_led.c
+++ b/drivers/staging/r8188eu/core/rtw_led.c
@@ -41,6 +41,7 @@ void DeInitLed871x(struct LED_871x *pLed)
{
cancel_delayed_work_sync(&pLed->blink_work);
ResetLedStatus(pLed);
+ SwLedOff(pLed->padapter, pLed);
}
static void SwLedBlink1(struct LED_871x *pLed)
--
2.30.2