Re: [PATCH] lontium-lt9611: check a different register bit for HDMI sensing

From: Vinod Koul
Date: Tue Nov 30 2021 - 00:31:10 EST


On 16-11-21, 18:07, Peter Collingbourne wrote:
> It has been observed that with certain monitors such as the HP Z27n,
> the register 0x825e reads a value of 0x79 when the HDMI cable is
> connected and 0x78 when it is disconnected, i.e. bit 0 appears
> to correspond to the HDMI connection status and bit 2 is never
> set. Therefore, change the driver to check bit 0 instead of bit 2.

So we have got limited information on this but BIT-2 seems to be related
to HPD and empirical data from various monitors supports this, so this
seems the right thing to do.

Reviewed-by: Vinod Koul <vkoul@xxxxxxxxxx>

--
~Vinod