Re: [PATCH v3 1/5] clk: samsung: clk-pll: Implement pll0822x PLL type

From: Sylwester Nawrocki
Date: Sat Oct 09 2021 - 16:25:07 EST


On 08.10.2021 17:43, Sam Protsenko wrote:
pll0822x PLL is used in Exynos850 SoC for top-level integer PLLs. The
code was derived from very similar pll35xx type, with next differences:

1. Lock time for pll0822x is 150*P_DIV, when for pll35xx it's 270*P_DIV
2. It's not suggested in Exynos850 TRM that S_DIV change doesn't require
performing PLL lock procedure (which is done in pll35xx
implementation)

When defining pll0822x type, CON3 register offset should be provided as
a "con" parameter of PLL() macro, like this:

PLL(pll_0822x, 0, "fout_shared0_pll", "oscclk",
PLL_LOCKTIME_PLL_SHARED0, PLL_CON3_PLL_SHARED0,
exynos850_shared0_pll_rates),

To define PLL rates table, one can use PLL_35XX_RATE() macro, e.g.:

PLL_35XX_RATE(26 * MHZ, 1600 * MHZ, 800, 13, 0)

as it's completely appropriate for pl0822x type and there is no sense in
duplicating that.

If bit #1 (MANUAL_PLL_CTRL) is not set in CON1 register, it won't be
possible to set new rate, with next error showing in kernel log:

Could not lock PLL fout_shared1_pll

That can happen for example if bootloader clears that bit beforehand.
PLL driver doesn't account for that, so if MANUAL_PLL_CTRL bit was
cleared, it's assumed it was done for a reason and it shouldn't be
possible to change that PLL's rate at all.

Signed-off-by: Sam Protsenko<semen.protsenko@xxxxxxxxxx>
Reviewed-by: Krzysztof Kozlowski<krzysztof.kozlowski@xxxxxxxxxxxxx>
Acked-by: Chanwoo Choi<cw00.choi@xxxxxxxxxxx>

Applied, thanks.