[PATCH 01/13] ASoC: soc-pcm: Don't reconnect an already active BE

From: Sameer Pujar
Date: Fri Aug 27 2021 - 05:38:27 EST


In some cases, multiple FE components have the same BE component in their
respective DPCM paths. One such example would be a mixer component, which
can receive two or more inputs and sends a mixed output. In such cases,
to avoid reconfiguration of already active DAI (mixer output DAI in this
case), check the BE stream state to filter out the redundancy.

In summary, allow connection of BE if the respective current stream state
is either NEW or CLOSED.

Signed-off-by: Sameer Pujar <spujar@xxxxxxxxxx>
---
sound/soc/soc-pcm.c | 4 ++++
1 file changed, 4 insertions(+)

diff --git a/sound/soc/soc-pcm.c b/sound/soc/soc-pcm.c
index 48f71bb..e30cb5a 100644
--- a/sound/soc/soc-pcm.c
+++ b/sound/soc/soc-pcm.c
@@ -1395,6 +1395,10 @@ static int dpcm_add_paths(struct snd_soc_pcm_runtime *fe, int stream,
if (!fe->dpcm[stream].runtime && !fe->fe_compr)
continue;

+ if ((be->dpcm[stream].state != SND_SOC_DPCM_STATE_NEW) &&
+ (be->dpcm[stream].state != SND_SOC_DPCM_STATE_CLOSE))
+ continue;
+
/* newly connected FE and BE */
err = dpcm_be_connect(fe, be, stream);
if (err < 0) {
--
2.7.4