[Ping for Dmitry] Re: [PATCH v5 3/3] iio: adc: add ADC driver for the TI TSC2046 controller

From: Oleksij Rempel
Date: Tue Apr 13 2021 - 05:31:22 EST


Hi Dmitry,

probably this mail passed under your radar. Can you please add your
statement here.

On Mon, Mar 29, 2021 at 11:58:26AM +0100, Jonathan Cameron wrote:
> On Mon, 29 Mar 2021 09:31:31 +0200
> Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx> wrote:
>
> > Basically the TI TSC2046 touchscreen controller is 8 channel ADC optimized for
> > the touchscreen use case. By implementing it as an IIO ADC device, we can
> > make use of resistive-adc-touch and iio-hwmon drivers.
> >
> > Polled readings are currently not implemented to keep this patch small, so
> > iio-hwmon will not work out of the box for now.
> >
> > So far, this driver was tested with a custom version of resistive-adc-touch driver,
> > since it needs to be extended to make use of Z1 and Z2 channels. The X/Y
> > are working without additional changes.
> >
> > Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
> > Reviewed-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx>
> Hi Oleksij,
>
> Couple of things in here I missed before, but big question is still whether
> Dmitry is happy with what you mention in the cover letter:
>
> "This driver can replace drivers/input/touchscreen/ads7846.c and has
> following advantages over it:
> - less code to maintain
> - shared code paths (resistive-adc-touch, iio-hwmon, etc)
> - can be used as plain IIO ADC to investigate signaling issues or test
> real capacity of the plates and attached low-pass filters
> (or use the touchscreen as a microphone if you like ;) )"
>
> So two things that need addressing in here are
> iio_dev->name (part number, not hybrid of that an spi device name)
> Why oversampling is DT rather than userspace controllable.
> For that I'm looking for clear reasoning for the choice.

Regards,
Oleksij
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |