Re: [PATCH 04/38] dt-bindings: power: supply: bq25890: Convert to DT schema format

From: Sebastian Reichel
Date: Tue Mar 16 2021 - 12:47:20 EST


Hi,

On Mon, Mar 15, 2021 at 12:21:34PM -0600, Rob Herring wrote:
> On Fri, Mar 12, 2021 at 8:44 AM Sebastian Reichel
> <sebastian.reichel@xxxxxxxxxxxxx> wrote:
> > + ti,ibatcomp-clamp-microvolt:
> > + $ref: /schemas/types.yaml#/definitions/uint32
> > + description: max. charging voltage adjustment due to expected voltage drop on in-series resistor
>
> You don't need a type $ref on properties with a standard unit suffix.
> Though it looks like there's some non-standard ones (-microvolts) in
> the series.

Ok. Unfortunately most properties in this series use non-standard
ones :(. Newer bindings using common properties have already been
written in YAML and/or make use of simple-battery.

Can we have a warning for this in the dt_binding_check? Maybe
something like

superfluous $ref for property with standard suffix

-- Sebastian