Re: [RFC PATCH 1/7] dt_bindings: Add protection limit properties

From: Rob Herring
Date: Fri Mar 05 2021 - 14:31:36 EST


On Thu, Feb 11, 2021 at 02:34:17PM +0200, Matti Vaittinen wrote:
> Support specifying protection/error/warning limits for regulator
> over current, over temperature and over/under voltage.
>
> Most of the PMICs support only "protection" feature but few
> setups do also support error/warning level indications.
>
> On many ICs most of the protection limits can't actually be set.
> But for example the ampere limit for over-current protection on ROHM
> BD9576 can be configured - or feature can be completely disabled.
>
> Provide limit setting for all protections/errors for the sake of
> the completeness and do that using own properties for all so that
> not all users would need to set all levels when only one or few are
> supported.
>
> Signed-off-by: Matti Vaittinen <matti.vaittinen@xxxxxxxxxxxxxxxxx>
> ---
> .../bindings/regulator/regulator.yaml | 82 +++++++++++++++++++
> 1 file changed, 82 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/regulator/regulator.yaml b/Documentation/devicetree/bindings/regulator/regulator.yaml
> index 6d0bc9cd4040..47fff75f0554 100644
> --- a/Documentation/devicetree/bindings/regulator/regulator.yaml
> +++ b/Documentation/devicetree/bindings/regulator/regulator.yaml
> @@ -117,6 +117,88 @@ properties:
> description: Enable over current protection.
> type: boolean
>
> + regulator-over-current-protection-microamp:

Kind of long and 'current' is implied by 'microamp'. Perhaps
regulator-oc-protection-microamp and similar.

> + description: Set over current protection limit. This is a limit where
> + hardware performs emergency shutdown. Zero can be passed to disable
> + protection and value '1' indicates that protection should be enabled but
> + limit setting can be omitted.
> +
> + regulator-over-current-error-microamp:
> + description: Set over current error limit. This is a limit where part of
> + the hardware propably is malfunctional and damage prevention is requested.
> + Zero can be passed to disable error detection and value '1' indicates
> + that detection should be enabled but limit setting can be omitted.
> +
> + regulator-over-current-warn-microamp:
> + description: Set over current warning limit. This is a limit where hardware
> + is assumed still to be functional but approaching limit where it gets
> + damaged. Recovery actions should be initiated. Zero can be passed to
> + disable detection and value '1' indicates that detection should
> + be enabled but limit setting can be omitted.
> +
> + regulator-over-voltage-protection-microvolt:
> + description: Set over voltage protection limit. This is a limit where
> + hardware performs emergency shutdown. Zero can be passed to disable
> + protection and value '1' indicates that protection should be enabled but
> + limit setting can be omitted. Limit is given as microvolt offset from
> + voltage set to regulator.
> +
> + regulator-over-voltage-error-microvolt:
> + description: Set over voltage error limit. This is a limit where part of
> + the hardware propably is malfunctional and damage prevention is requested
> + Zero can be passed to disable error detection and value '1' indicates
> + that detection should be enabled but limit setting can be omitted. Limit
> + is given as microvolt offset from voltage set to regulator.
> +
> + regulator-over-voltage-warn-microvolt:
> + description: Set over voltage warning limit. This is a limit where hardware
> + is assumed still to be functional but approaching limit where it gets
> + damaged. Recovery actions should be initiated. Zero can be passed to
> + disable detection and value '1' indicates that detection should
> + be enabled but limit setting can be omitted. Limit is given as microvolt
> + offset from voltage set to regulator.
> +
> + regulator-under-voltage-protection-microvolt:
> + description: Set over under voltage protection limit. This is a limit where
> + hardware performs emergency shutdown. Zero can be passed to disable
> + protection and value '1' indicates that protection should be enabled but
> + limit setting can be omitted. Limit is given as microvolt offset from
> + voltage set to regulator.
> +
> + regulator-under-voltage-error-microvolt:
> + description: Set under voltage error limit. This is a limit where part of
> + the hardware propably is malfunctional and damage prevention is requested
> + Zero can be passed to disable error detection and value '1' indicates
> + that detection should be enabled but limit setting can be omitted. Limit
> + is given as microvolt offset from voltage set to regulator.
> +
> + regulator-under-voltage-warn-microvolt:
> + description: Set over under voltage warning limit. This is a limit where
> + hardware is assumed still to be functional but approaching limit where
> + it gets damaged. Recovery actions should be initiated. Zero can be passed
> + to disable detection and value '1' indicates that detection should
> + be enabled but limit setting can be omitted. Limit is given as microvolt
> + offset from voltage set to regulator.
> +
> + regulator-over-temperature-protection-kelvin:
> + description: Set over temperature protection limit. This is a limit where
> + hardware performs emergency shutdown. Zero can be passed to disable
> + protection and value '1' indicates that protection should be enabled but
> + limit setting can be omitted.
> +
> + regulator-over-temperature-error-kelvin:
> + description: Set over temperature error limit. This is a limit where part of
> + the hardware propably is malfunctional and damage prevention is requested
> + Zero can be passed to disable error detection and value '1' indicates
> + that detection should be enabled but limit setting can be omitted.
> +
> + regulator-over-temperature-warn-kelvin:
> + description: Set over temperature warning limit. This is a limit where
> + hardware is assumed still to be functional but approaching limit where it
> + gets damaged. Recovery actions should be initiated. Zero can be passed to
> + disable detection and value '1' indicates that detection should
> + be enabled but limit setting can be omitted.
> +
> regulator-active-discharge:
> description: |
> tristate, enable/disable active discharge of regulators. The values are:
> --
> 2.25.4
>
>
> --
> Matti Vaittinen, Linux device drivers
> ROHM Semiconductors, Finland SWDC
> Kiviharjunlenkki 1E
> 90220 OULU
> FINLAND
>
> ~~~ "I don't think so," said Rene Descartes. Just then he vanished ~~~
> Simon says - in Latin please.
> ~~~ "non cogito me" dixit Rene Descarte, deinde evanescavit ~~~
> Thanks to Simon Glass for the translation =]