Re: [PATCH 4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs

From: Andy Shevchenko
Date: Thu Mar 04 2021 - 04:53:02 EST


On Thu, Mar 4, 2021 at 9:27 AM Henning Schild
<henning.schild@xxxxxxxxxxx> wrote:

> Siemens industrial PCs unfortunately can not always be properly
> identified the way we used to. An earlier commit introduced code that
> allows proper identification without looking at DMI strings that could
> differ based on product branding.
> Switch over to that proper way and revert commits that used to collect
> the machines based on unstable strings.

> +#include <linux/platform_data/x86/simatic-ipc.h>

> +static int pmc_clk_is_critical(const struct dmi_system_id *d)
> +{
> + int ret = true;
> + u32 station_id;
> +
> + if (!strcmp(d->ident, "SIEMENS AG")) {
> + if (dmi_walk(simatic_ipc_find_dmi_entry_helper, &station_id))
> + ret = false;
> + else
> + ret = (station_id == SIMATIC_IPC_IPC227E ||
> + station_id == SIMATIC_IPC_IPC277E);
> + }
> +
> + return ret;

Much easier to rewrite it as

if (strcmp(...)) // BTW, do we have a dmi_* helper for that?
return true;

if (dmi_walk)
return false;

return station_id == || ...;

> +}

Maybe instead you can rewrite it as a callback in DMI table which
changes a (global, yeah) variable that you simply reassign...



> if (d) {
> - clk_data->critical = true;
> - pr_info("%s critclks quirk enabled\n", d->ident);
> + clk_data->critical = pmc_clk_is_critical(d);
> + if (clk_data->critical)
> + pr_info("%s critclks quirk enabled\n", d->ident);
> }

...somewhere here?

Like
clk_data->critical = global_var;
if (...)
pr_info();

It seems it will reduce burden on a callback by dropping strcmp() call.

--
With Best Regards,
Andy Shevchenko