[PATCH 0/3] resolve read hystersis return invalid argument issue for hid sensors

From: Ye Xiang
Date: Wed Jan 20 2021 - 02:46:39 EST


This patch series move get sensitivity attribute to common layer and
resolve read hystersis return invalid argument issue for hid sensors als,
incli-3d, rotation, and press on intel ISH Platform.

Ye Xiang (3):
iio: hid-sensors: Move get sensitivity attribute to hid-sensor-common
hid-sensor-common: Add relative sensitivity check
hid-sensors: Add more data fields for sensitivity checking

drivers/iio/accel/hid-sensor-accel-3d.c | 23 +++++--------
.../hid-sensors/hid-sensor-attributes.c | 26 +++++++++++++-
drivers/iio/gyro/hid-sensor-gyro-3d.c | 19 ++++-------
drivers/iio/humidity/hid-sensor-humidity.c | 16 ++++-----
drivers/iio/light/hid-sensor-als.c | 20 +++++------
drivers/iio/light/hid-sensor-prox.c | 27 +++++----------
drivers/iio/magnetometer/hid-sensor-magn-3d.c | 34 ++++++-------------
drivers/iio/orientation/hid-sensor-incl-3d.c | 20 +++++------
drivers/iio/orientation/hid-sensor-rotation.c | 24 ++++++-------
.../position/hid-sensor-custom-intel-hinge.c | 20 ++++-------
drivers/iio/pressure/hid-sensor-press.c | 20 +++++------
.../iio/temperature/hid-sensor-temperature.c | 16 ++++-----
drivers/rtc/rtc-hid-sensor-time.c | 4 ++-
include/linux/hid-sensor-hub.h | 4 ++-
include/linux/hid-sensor-ids.h | 1 +
15 files changed, 122 insertions(+), 152 deletions(-)

--
2.17.1