Re: [PATCH 1/4] net: sfp: add workaround for Realtek RTL8672 and RTL9601C chips

From: Andrew Lunn
Date: Thu Dec 31 2020 - 10:11:14 EST


On Thu, Dec 31, 2020 at 01:14:10PM +0100, Pali Rohár wrote:
> On Wednesday 30 December 2020 19:09:58 Russell King - ARM Linux admin wrote:
> > On Wed, Dec 30, 2020 at 06:43:07PM +0100, Pali Rohár wrote:
> > > On Wednesday 30 December 2020 18:13:15 Andrew Lunn wrote:
> > > > Hi Pali
> > > >
> > > > I have to agree with Russell here. I would rather have no diagnostics
> > > > than untrustable diagnostics.
> > >
> > > Ok!
> > >
> > > So should we completely skip hwmon_device_register_with_info() call
> > > if (i2c_block_size < 2) ?
> >
> > I don't think that alone is sufficient - there's also the matter of
> > ethtool -m which will dump that information as well, and we don't want
> > to offer it to userspace in an unreliable form.
>
> Any idea/preference how to disable access to these registers?
>
> > For reference, here is what SFF-8472 which defines the diagnostics, says
> > about this:
> >
> > To guarantee coherency of the diagnostic monitoring data, the host is
> > required to retrieve any multi-byte fields from the diagnostic
> > monitoring data structure (IE: Rx Power MSB - byte 104 in A2h, Rx Power
> > LSB - byte 105 in A2h) by the use of a single two-byte read sequence
> > across the two-wire interface interface.
> >
> > The transceiver is required to ensure that any multi-byte fields which
> > are updated with diagnostic monitoring data (e.g. Rx Power MSB - byte
> > 104 in A2h, Rx Power LSB - byte 105 in A2h) must have this update done
> > in a fashion which guarantees coherency and consistency of the data. In
> > other words, the update of a multi-byte field by the transceiver must
> > not occur such that a partially updated multi-byte field can be
> > transferred to the host. Also, the transceiver shall not update a
> > multi-byte field within the structure during the transfer of that
> > multi-byte field to the host, such that partially updated data would be
> > transferred to the host.
> >
> > The first paragraph is extremely definitive in how these fields shall
> > be read atomically - by a _single_ two-byte read sequence. From what
> > you are telling us, these modules do not support that. Therefore, by
> > definition, they do *not* support proper and reliable reporting of
> > diagnostic data, and are non-conformant with the SFP MSAs.
> >
> > So, they are basically broken, and the diagnostics can't be used to
> > retrieve data that can be said to be useful.
>
> I agree they are broken. We really should disable access to those 16bit
> registers.
>
> Anyway here is "datasheet" to some CarlitoxxPro SFP:
> https://www.docdroid.net/hRsJ560/cpgos03-0490v2-datasheet-10-pdf
>
> And on page 10 is written:
>
> The I2C system can support the mode of random address / single
> byteread which conform to SFF-8431.
>
> Which seems to be wrong.

Searching around, i found:

http://read.pudn.com/downloads776/doc/3073304/RTL9601B-CG_Datasheet.pdf

It has two i2c busses, a master and a slave. The master bus can do
multi-byte transfers. The slave bus description says nothing in words
about multi-byte transfers, but the diagram shows only single byte
transfers.

So any SFP based around this device is broken.

The silly thing is, it is reading/writing from a shadow SRAM. The CPU
is not directly involved in an I2C transaction. So it could easily
read multiple bytes from the SRAM and return them. But it would still
need a synchronisation method to handle writes from the CPU to the
SRAM, in order to make these word values safe.

Andrew