Re: [PATCH] clk: meson: g12a: select COMMON_CLK_MESON_VID_PLL_DIV

From: Jerome Brunet
Date: Fri Dec 04 2020 - 10:21:31 EST



On Thu 03 Dec 2020 at 23:26, Arnd Bergmann <arnd@xxxxxxxxxx> wrote:

> From: Arnd Bergmann <arnd@xxxxxxxx>
>
> Without this, a g12a-only config produces a link error:
>
> aarch64-linux-ld: drivers/clk/meson/g12a.o:(.data+0xcb68): undefined reference to `meson_vid_pll_div_ro_ops'
>
> Fixes: 085a4ea93d54 ("clk: meson: g12a: add peripheral clock controller")
> Signed-off-by: Arnd Bergmann <arnd@xxxxxxxx>

Hi Arnd,

Thanks for sending this fix.

Same change has already been applied:
https://patchwork.kernel.org/project/linux-clk/patch/20201118190930.34352-1-khilman@xxxxxxxxxxxx/

It was part of my last PR to Stephen

Jerome

> ---
> drivers/clk/meson/Kconfig | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/drivers/clk/meson/Kconfig b/drivers/clk/meson/Kconfig
> index 034da203e8e0..9a8a548d839d 100644
> --- a/drivers/clk/meson/Kconfig
> +++ b/drivers/clk/meson/Kconfig
> @@ -110,6 +110,7 @@ config COMMON_CLK_G12A
> select COMMON_CLK_MESON_AO_CLKC
> select COMMON_CLK_MESON_EE_CLKC
> select COMMON_CLK_MESON_CPU_DYNDIV
> + select COMMON_CLK_MESON_VID_PLL_DIV
> select MFD_SYSCON
> help
> Support for the clock controller on Amlogic S905D2, S905X2 and S905Y2