Re: [PATCH v2 1/6] clk: actions: Fix h_clk for Actions S500 SoC

From: Manivannan Sadhasivam
Date: Fri Jun 26 2020 - 09:45:53 EST


On Wed, Jun 24, 2020 at 08:47:52PM +0300, Cristian Ciocaltea wrote:
> The h_clk clock in the Actions Semi S500 SoC clock driver has an
> invalid parent. Replace with the correct one.
>
> Signed-off-by: Cristian Ciocaltea <cristian.ciocaltea@xxxxxxxxx>

Reviewed-by: Manivannan Sadhasivam <manivannan.sadhasivam@xxxxxxxxxx>

You should add fixes tag for this patch and it needs to be backported as well.

Thanks,
Mani

> ---
> drivers/clk/actions/owl-s500.c | 2 +-
> 1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/clk/actions/owl-s500.c b/drivers/clk/actions/owl-s500.c
> index e2007ac4d235..0eb83a0b70bc 100644
> --- a/drivers/clk/actions/owl-s500.c
> +++ b/drivers/clk/actions/owl-s500.c
> @@ -183,7 +183,7 @@ static OWL_GATE(timer_clk, "timer_clk", "hosc", CMU_DEVCLKEN1, 27, 0, 0);
> static OWL_GATE(hdmi_clk, "hdmi_clk", "hosc", CMU_DEVCLKEN1, 3, 0, 0);
>
> /* divider clocks */
> -static OWL_DIVIDER(h_clk, "h_clk", "ahbprevdiv_clk", CMU_BUSCLK1, 12, 2, NULL, 0, 0);
> +static OWL_DIVIDER(h_clk, "h_clk", "ahbprediv_clk", CMU_BUSCLK1, 12, 2, NULL, 0, 0);
> static OWL_DIVIDER(rmii_ref_clk, "rmii_ref_clk", "ethernet_pll_clk", CMU_ETHERNETPLL, 1, 1, rmii_ref_div_table, 0, 0);
>
> /* factor clocks */
> --
> 2.27.0
>