Re: [PATCH v3] dt-bindings: arm: samsung: Convert Samsung Exynos IOMMU H/W, System MMU to dt-schema

From: Marek Szyprowski
Date: Wed Sep 11 2019 - 07:57:09 EST


Hi Krzyszotf,

On 2019-09-11 13:36, Krzysztof Kozlowski wrote:
> On Wed, 11 Sep 2019 at 13:05, Maciej Falkowski <m.falkowski@xxxxxxxxxxx> wrote:
>> Convert Samsung Exynos IOMMU H/W, System Memory Management Unit
>> to newer dt-schema format.
>>
>> Update clock description.
>>
>> Signed-off-by: Maciej Falkowski <m.falkowski@xxxxxxxxxxx>
>> Signed-off-by: Andrzej Hajda <a.hajda@xxxxxxxxxxx>
>> ---
>> Hi Krzysztof,
>>
>> Thank you for feedback.
>>
>> v3:
>>
>> - remove obsolete interrupts description and
>> set its maxItems to one. There are some incompatible
>> files which will be fixed with another patch.
> Driver stopped supporting two IRQ lines in commit
> 7222e8db2d506197ee183de0f9b76b3ad97e8c18 (iommu/exynos: Fix build
> errors). The second IRQ line in Exynos3250 DTS seems to be ignored.
>
> The patch now looks good to me:
> Reviewed-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx>
>
> However for some reasons you did not CC the IOMMU maintainers. Please
> use scripts/get_maintainer.pl to get the list of folks to CC.

Frankly I don't see any reason to spam IOMMU ml or maintainer with this
discussion about dt-binding conversion. This patch will be merged via dt
tree if I got it right.