Re: [PATCH v14 2/2] dt-bindings: spi: Document Renesas R-Car Gen3 RPC-IF controller bindings

From: masonccyang
Date: Thu Jul 18 2019 - 22:39:41 EST



Hi Geert,

Thanks for your review!

Will fix it as

+Renesas R-Car Gen3 RPC-IF controller Device Tree Bindings
+---------------------------------------------------------
+
+Required properties:
+- compatible: should be an SoC-specific compatible value, followed by
+ "renesas,rcar-gen3-rpc" as a fallback.
+ supported SoC-specific values are:
+ "renesas,r8a77980-rpc" (R-Car
V3H)
+ "renesas,r8a77995-rpc" (R-Car
D3)
+- reg: should contain three register areas:
+ first for the base address of RPC-IF registers,
+ second for the direct mapping read mode and
+ third for the write buffer area.
+- reg-names: should contain "regs", "dirmap" and "wbuf"
+- clocks: should contain the clock phandle/specifier pair for the module
clock.
+- clock-names: should contain "rpc"
+- power-domains: should contain the power domain phandle/secifier pair.
+- resets: should contain the reset controller phandle/specifier pair.
+- #address-cells: should be 1
+- #size-cells: should be 0
+
+ flash: should be represented by a subnode of the RPC-IF node,
+ which "compatible" property contains "jedec,spi-nor", it presents SPI
is used.
+
+Example:
+
+ rpc: spi@ee200000 {
+ compatible = "renesas,r8a77995-rpc",
"renesas,rcar-gen3-rpc";
+ reg = <0 0xee200000 0 0x200>, <0
0x08000000 0 0x4000000>,
+ <0 0xee208000 0 0x100>;
+ reg-names = "regs", "dirmap", "wbuf";
+ clocks = <&cpg CPG_MOD 917>;
+ clock-names = "rpc";
+ power-domains = <&sysc
R8A77995_PD_ALWAYS_ON>;
+ resets = <&cpg 917>;
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ flash@0 {
+ compatible =
"jedec,spi-nor";
+ reg = <0>;
+ spi-max-frequency =
<40000000>;
+ spi-tx-bus-width = <1>;
+ spi-rx-bus-width = <1>;
+ };
+ };

Is it OK ?

thanks & best regards,
Mason


CONFIDENTIALITY NOTE:

This e-mail and any attachments may contain confidential information
and/or personal data, which is protected by applicable laws. Please be
reminded that duplication, disclosure, distribution, or use of this e-mail
(and/or its attachments) or any part thereof is prohibited. If you receive
this e-mail in error, please notify us immediately and delete this mail as
well as its attachment(s) from your system. In addition, please be
informed that collection, processing, and/or use of personal data is
prohibited unless expressly permitted by personal data protection laws.
Thank you for your attention and cooperation.

Macronix International Co., Ltd.

=====================================================================



============================================================================

CONFIDENTIALITY NOTE:

This e-mail and any attachments may contain confidential information and/or personal data, which is protected by applicable laws. Please be reminded that duplication, disclosure, distribution, or use of this e-mail (and/or its attachments) or any part thereof is prohibited. If you receive this e-mail in error, please notify us immediately and delete this mail as well as its attachment(s) from your system. In addition, please be informed that collection, processing, and/or use of personal data is prohibited unless expressly permitted by personal data protection laws. Thank you for your attention and cooperation.

Macronix International Co., Ltd.

=====================================================================