Re: [PATCH v4 2/2] dt-bindings: mfd: max8998: Add charger subnode binding

From: Lee Jones
Date: Wed Jun 26 2019 - 09:06:32 EST


On Fri, 21 Jun 2019, PaweÅ Chmiel wrote:

> This patch adds devicetree bindings documentation for
> battery charging controller as the subnode of MAX8998 PMIC.

It makes sense to place this in:

Documentation/devicetree/bindings/power/supply/

And link to it from this file using the following syntax:

See: ../power/supply/<file>.txt

> Signed-off-by: PaweÅ Chmiel <pawel.mikolaj.chmiel@xxxxxxxxx>
> ---
> Changes from v3:
> - Property prefix should be maxim, not max8998
> - Describe what End of Charge in percent means
>
> Changes from v2:
> - Make charge-restart-level-microvolt optional.
> - Make charge-timeout-hours optional.
>
> Changes from v1:
> - Removed unneeded Fixes tag
> - Correct description of all charger values
> - Added missing property unit
> ---
> .../devicetree/bindings/mfd/max8998.txt | 26 +++++++++++++++++++
> 1 file changed, 26 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/mfd/max8998.txt b/Documentation/devicetree/bindings/mfd/max8998.txt
> index 5f2f07c09c90..368f787d6079 100644
> --- a/Documentation/devicetree/bindings/mfd/max8998.txt
> +++ b/Documentation/devicetree/bindings/mfd/max8998.txt
> @@ -48,6 +48,25 @@ Additional properties required if max8998,pmic-buck2-dvs-gpio is defined:
> - max8998,pmic-buck2-dvs-voltage: An array of 2 voltage values in microvolts
> for buck2 regulator that can be selected using dvs gpio.
>
> +Charger: Configuration for battery charging controller should be added
> +inside a child node named 'charger'.
> + Required properties:
> + - maxim,end-of-charge-percentage: End of Charge in percent.
> + When the charge current in constant-voltage phase drops below
> + end-of-charge-percentage of it's start value, charging is terminated.
> + If value equals 0, leave it unchanged. Otherwise it should be value
> + from 10 to 45 by 5 step.
> +
> + Optional properties:
> + - maxim,charge-restart-threshold: Charge restart threshold in millivolts.
> + If property is not present, this will be disabled.
> + Valid values are: 0, 100, 150, 200. If the value equals 0, leave it
> + unchanged.
> +
> + - maxim,charge-timeout: Charge timeout in hours. If property is not
> + present, this will be disabled. Valid values are: 0, 5, 6, 7.
> + If the value equals 0, leave it unchanged.
> +
> Regulators: All the regulators of MAX8998 to be instantiated shall be
> listed in a child node named 'regulators'. Each regulator is represented
> by a child node of the 'regulators' node.
> @@ -97,6 +116,13 @@ Example:
> max8998,pmic-buck2-dvs-gpio = <&gpx0 0 3 0 0>; /* SET3 */
> max8998,pmic-buck2-dvs-voltage = <1350000>, <1300000>;
>
> + /* Charger configuration */
> + charger {
> + maxim,end-of-charge-percentage = <20>;
> + maxim,charge-restart-threshold = <100>;
> + maxim,charge-timeout = <7>;
> + };
> +
> /* Regulators to instantiate */
> regulators {
> ldo2_reg: LDO2 {

--
Lee Jones [æçæ]
Linaro Services Technical Lead
Linaro.org â Open source software for ARM SoCs
Follow Linaro: Facebook | Twitter | Blog