[PATCH V3 0/2] hwmon: pwm-fan: Add optional regulator support

From: Stefan Wahren
Date: Fri Feb 22 2019 - 08:46:38 EST


This small series implements the optional regulator support for the
pwm-fan driver.

Changes in V3:
- simplify error case in probing code
- return regulator error code in pm callbacks

Changes in V2:
- address Guenter's comments:
- handle error case first
- drop ENOSYS handling
- implement more consistent bail out handling
- enable regulator before setup PWM
- make sure we disable regulator if probe fails

Stefan Wahren (2):
dt-bindings: hwmon: Add optional regulator support to pwm-fan
hwmon: pwm-fan: Add optional regulator support

.../devicetree/bindings/hwmon/pwm-fan.txt | 3 ++
drivers/hwmon/pwm-fan.c | 43 +++++++++++++++++++++-
2 files changed, 45 insertions(+), 1 deletion(-)

--
2.7.4