[PATCH/RFT 3/6] i2c: designware: set SDA as output for recovery

From: Wolfram Sang
Date: Fri Jul 13 2018 - 17:10:06 EST


This allows for sending STOP when generating pulses which is much more
robust because it will bring clients into a default state.

Signed-off-by: Wolfram Sang <wsa+renesas@xxxxxxxxxxxxxxxxxxxx>
---
drivers/i2c/busses/i2c-designware-master.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/i2c/busses/i2c-designware-master.c b/drivers/i2c/busses/i2c-designware-master.c
index a546db80f53e..25981efc844e 100644
--- a/drivers/i2c/busses/i2c-designware-master.c
+++ b/drivers/i2c/busses/i2c-designware-master.c
@@ -674,7 +674,7 @@ static int i2c_dw_init_recovery_info(struct dw_i2c_dev *dev)
}
rinfo->scl_gpiod = gpio;

- gpio = devm_gpiod_get_optional(dev->dev, "sda", GPIOD_IN);
+ gpio = devm_gpiod_get_optional(dev->dev, "sda", GPIOD_OUT_HIGH_OPEN_DRAIN);
if (IS_ERR(gpio))
return PTR_ERR(gpio);
rinfo->sda_gpiod = gpio;
--
2.11.0