[PATCH] iio: pressure: bmp280: remove unused options from device tree documentation

From: Brian Masney
Date: Tue Jul 10 2018 - 21:33:50 EST


There are several options in the device tree documentation that are
no longer relevant for the current in-kernel bmp280 driver so this patch
removes them.

Signed-off-by: Brian Masney <masneyb@xxxxxxxxxxxxx>
---
Documentation/devicetree/bindings/iio/pressure/bmp085.txt | 7 -------
1 file changed, 7 deletions(-)

diff --git a/Documentation/devicetree/bindings/iio/pressure/bmp085.txt b/Documentation/devicetree/bindings/iio/pressure/bmp085.txt
index c7198a03c906..abcab02504fb 100644
--- a/Documentation/devicetree/bindings/iio/pressure/bmp085.txt
+++ b/Documentation/devicetree/bindings/iio/pressure/bmp085.txt
@@ -8,10 +8,6 @@ Required properties:
"bosch,bme280"

Optional properties:
-- chip-id: configurable chip id for non-default chip revisions
-- temp-measurement-period: temperature measurement period (milliseconds)
-- default-oversampling: default oversampling value to be used at startup,
- value range is 0-3 with rising sensitivity.
- interrupt-parent: should be the phandle for the interrupt controller
- interrupts: interrupt mapping for IRQ
- reset-gpios: a GPIO line handling reset of the sensor: as the line is
@@ -24,9 +20,6 @@ Example:
pressure@77 {
compatible = "bosch,bmp085";
reg = <0x77>;
- chip-id = <10>;
- temp-measurement-period = <100>;
- default-oversampling = <2>;
interrupt-parent = <&gpio0>;
interrupts = <25 IRQ_TYPE_EDGE_RISING>;
reset-gpios = <&gpio0 26 GPIO_ACTIVE_LOW>;
--
2.17.1