[RESEND] thermal: hwmon: Properly report critical temperature in sysfs

From: Krzysztof Kozlowski
Date: Wed Dec 28 2016 - 12:35:43 EST


In the critical sysfs entry the thermal hwmon was returning wrong
temperature to the user-space. It was reporting the temperature of the
first trip point instead of the temperature of critical trip point.

For example:
/sys/class/hwmon/hwmon0/temp1_crit:50000
/sys/class/thermal/thermal_zone0/trip_point_0_temp:50000
/sys/class/thermal/thermal_zone0/trip_point_0_type:active
/sys/class/thermal/thermal_zone0/trip_point_3_temp:120000
/sys/class/thermal/thermal_zone0/trip_point_3_type:critical

Since commit e68b16abd91d ("thermal: add hwmon sysfs I/F") the driver
have been registering a sysfs entry if get_crit_temp() callback was
provided. However when accessed, it was calling get_trip_temp() instead
of the get_crit_temp().

Fixes: e68b16abd91d ("thermal: add hwmon sysfs I/F")
Cc: <stable@xxxxxxxxxxxxxxx>
Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx>
---
drivers/thermal/thermal_hwmon.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/thermal/thermal_hwmon.c b/drivers/thermal/thermal_hwmon.c
index c41c7742903a..2dcd4194d103 100644
--- a/drivers/thermal/thermal_hwmon.c
+++ b/drivers/thermal/thermal_hwmon.c
@@ -98,7 +98,7 @@ temp_crit_show(struct device *dev, struct device_attribute *attr, char *buf)
int temperature;
int ret;

- ret = tz->ops->get_trip_temp(tz, 0, &temperature);
+ ret = tz->ops->get_crit_temp(tz, &temperature);
if (ret)
return ret;

--
2.9.3