[PATCH v5 1/2] iio: Implement counter channel type and info constants

From: William Breathitt Gray
Date: Wed Sep 28 2016 - 14:00:17 EST


Quadrature encoders, such as rotary encoders and linear encoders, are
devices which are capable of encoding the relative position and
direction of motion of a shaft. This patch introduces several IIO
constants for supporting quadrature encoder counter devices.

IIO_COUNT: Current count (main data provided by the counter device)
IIO_INDEX: Counter device index value

Signed-off-by: William Breathitt Gray <vilhelm.gray@xxxxxxxxx>
---
Documentation/ABI/testing/sysfs-bus-iio | 18 ++++++++++++++++++
drivers/iio/industrialio-core.c | 2 ++
include/uapi/linux/iio/types.h | 2 ++
3 files changed, 22 insertions(+)

diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index fee35c0..b8f220f 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -329,6 +329,7 @@ What: /sys/bus/iio/devices/iio:deviceX/in_pressure_scale
What: /sys/bus/iio/devices/iio:deviceX/in_humidityrelative_scale
What: /sys/bus/iio/devices/iio:deviceX/in_velocity_sqrt(x^2+y^2+z^2)_scale
What: /sys/bus/iio/devices/iio:deviceX/in_illuminance_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_countY_scale
KernelVersion: 2.6.35
Contact: linux-iio@xxxxxxxxxxxxxxx
Description:
@@ -1579,3 +1580,20 @@ Contact: linux-iio@xxxxxxxxxxxxxxx
Description:
Raw (unscaled no offset etc.) electric conductivity reading that
can be processed to siemens per meter.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_countY_raw
+KernelVersion: 4.9
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Raw counter device counts from channel Y. For quadrature
+ counters, multiplication by an available [Y]_scale results in
+ the counts of a single quadrature signal phase from channel Y.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_indexY_raw
+KernelVersion: 4.9
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Raw counter device index value from channel Y. This attribute
+ provides an absolute positional reference (e.g. a pulse once per
+ revolution) which may be used to home positional systems as
+ required.
diff --git a/drivers/iio/industrialio-core.c b/drivers/iio/industrialio-core.c
index fc340ed..649725b 100644
--- a/drivers/iio/industrialio-core.c
+++ b/drivers/iio/industrialio-core.c
@@ -81,6 +81,8 @@ static const char * const iio_chan_type_name_spec[] = {
[IIO_PH] = "ph",
[IIO_UVINDEX] = "uvindex",
[IIO_ELECTRICALCONDUCTIVITY] = "electricalconductivity",
+ [IIO_COUNT] = "count",
+ [IIO_INDEX] = "index",
};

static const char * const iio_modifier_names[] = {
diff --git a/include/uapi/linux/iio/types.h b/include/uapi/linux/iio/types.h
index 22e5e58..e54d14a 100644
--- a/include/uapi/linux/iio/types.h
+++ b/include/uapi/linux/iio/types.h
@@ -40,6 +40,8 @@ enum iio_chan_type {
IIO_PH,
IIO_UVINDEX,
IIO_ELECTRICALCONDUCTIVITY,
+ IIO_COUNT,
+ IIO_INDEX,
};

enum iio_modifier {
--
2.7.3