Re: [PATCH 2/2] regulator: core: add support for configuring turn-ontime through constraints

From: Mark Brown
Date: Tue Sep 10 2013 - 12:34:34 EST


On Tue, Sep 10, 2013 at 06:44:40PM +0530, Laxman Dewangan wrote:

> Here my intention for turn-on time is the time from OFF state to ON
> state and the ON voltage settled on this time.
> This time is separate from underlying enable time of the device i.e.
> will not get added.
> We observe in some of platform that some of regulator is taking more
> time than time given as per datasheet.
> Yes, completely agree that this is not the data provided normally,
> just we observe on scope that some of platform shows more than the
> datasheet value and hence this patch.

So, put this in the binding document then! :P This was more a request
to improve the detail in the binding than anything else.

Attachment: signature.asc