[PATCH v2]serial: 8250_pci: add device id for a kind of Multi-I/OController based on NetMos Technology PCI 9835

From: Wang YanQing
Date: Tue Mar 05 2013 - 10:44:11 EST


I get a Multi-I/O Controller below:
01:08.0 Communication controller: NetMos Technology PCI 9835 Multi-I/O Controller (rev 01)
Subsystem: LSI Logic / Symbios Logic 1P2S
Control: I/O+ Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx-
Status: Cap- 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
Interrupt: pin A routed to IRQ 20
Region 0: I/O ports at e050 [size=8]
Region 1: I/O ports at e040 [size=8]
Region 2: I/O ports at e030 [size=8]
Region 3: I/O ports at e020 [size=8]
Region 4: I/O ports at e010 [size=8]
Region 5: I/O ports at e000 [size=16]

I get below from pci.ids:
9710 NetMos Technology
9835 PCI 9835 Multi-I/O Controller
1000 0002 2S (16C550 UART)
1000 0012 1P2S
I have tested 8250_pci.c, it works well with it,
so we just need add the device id to the deivce
id table.

Signed-off-by: Wang YanQing <udknight@xxxxxxxxx>
---
Changes:
V1-V2:
1: use a better descriptive subject
2: add more detail log

Thanks
drivers/tty/serial/8250/8250_pci.c | 4 ++++
1 file changed, 4 insertions(+)

diff --git a/drivers/tty/serial/8250/8250_pci.c b/drivers/tty/serial/8250/8250_pci.c
index 5805f89..2120840 100644
--- a/drivers/tty/serial/8250/8250_pci.c
+++ b/drivers/tty/serial/8250/8250_pci.c
@@ -4800,6 +4800,10 @@ static struct pci_device_id serial_pci_tbl[] = {
PCI_VENDOR_ID_IBM, 0x0299,
0, 0, pbn_b0_bt_2_115200 },

+ { PCI_VENDOR_ID_NETMOS, PCI_DEVICE_ID_NETMOS_9835,
+ 0x1000, 0x0012,
+ 0, 0, pbn_b0_bt_2_115200 },
+
{ PCI_VENDOR_ID_NETMOS, PCI_DEVICE_ID_NETMOS_9901,
0xA000, 0x1000,
0, 0, pbn_b0_1_115200 },
--
1.7.12.4.dirty
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/