Re: [PATCH 06/18] power: ab8500_bm: Recharge condition not optimalfor battery

From: Lee Jones
Date: Wed Jan 16 2013 - 03:47:05 EST


On Tue, 15 Jan 2013, Anton Vorontsov wrote:

> On Fri, Jan 11, 2013 at 01:12:54PM +0000, Lee Jones wrote:
> > From: Marcus Cooper <marcus.xm.cooper@xxxxxxxxxxxxxx>
> >
> > Today the battery recharge is determined with a voltage threshold. This
> > voltage threshold is only valid when the battery is relaxed. In charging
> > algorithm the voltage read is the loaded battery voltage and no
> > compensation is done to get the relaxed voltage. When maintenance
> > charging is not selected, this makes the recharging condition to almost
> > immediately activate when there is a discharge present on the battery.
> >
> > Depending on which vendor the battery comes from this behavior can wear
> > out the battery much faster than normal.
> >
> > The fuelgauge driver is responsible to monitor the actual battery
> > capacity and is able to estimate the remaining capacity. It is better to
> > use the remaining capacity as a limit to determine when battery should
> > be recharged.
> >
> > Signed-off-by: Lee Jones <lee.jones@xxxxxxxxxx>
> > Signed-off-by: Marcus Cooper <marcus.xm.cooper@xxxxxxxxxxxxxx>
> > Reviewed-by: Hakan BERG <hakan.berg@xxxxxxxxxxxxxx>
> > Reviewed-by: Jonas ABERG <jonas.aberg@xxxxxxxxxxxxxx>
> > ---
> > + .maint_thres = 95,
> > .user_cap_limit = 15,
> > .maint_thres = 97,
> > };
>
> 95 or 97? These are both specified. I removed 97, assuming it was a merge
> error on your side. But please double check, it could be that you really
> want 97 here.

You did the correct thing, thanks.

--
Lee Jones
Linaro ST-Ericsson Landing Team Lead
Linaro.org â Open source software for ARM SoCs
Follow Linaro: Facebook | Twitter | Blog
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/