RE: [PATCH v2] charger_manager: update charge profile upontemperature zone change

From: Pallala, Ramakrishna
Date: Wed May 09 2012 - 02:48:00 EST


> >
> > As part of charge enablement we generally program charge current,
> > charge voltage into the charger chip.
> >
> > We can pass the charging parameters CC and CV in two ways.
> > 1. Add these params in charger_desc struct and the charger regulator
> > can get these params using container_of() call? but becomes complex.
> >
> > 2. use regulator_set_voltage()/regulator_set_current_limit() functions
> > to set the CV and CC params.
> > but not suitable as is, we have add support in regulator framework
> >
>
> regulator_ops has support for set_current_limit and set_voltage. Can we use the same for
> setting CC and CV?

I feel set_voltage()/set_current_limit() is more suitable to control input source current and
voltage, but CC and CV are more like output parameters from charger.

Thanks,
Ram