Re: [PATCH] power_supply: Clean up wm97xx_battery warnings

From: Marek Vasut
Date: Fri Jan 29 2010 - 05:11:30 EST


Dne St 27. ledna 2010 21:45:35 Mark Brown napsal(a):
> Staticise work_lock (nothing outside the driver has any reason to
> see it) and specify dev when requesting the charger IRQ (since that's
> what we pass in when we free it).
>
> Signed-off-by: Mark Brown <broonie@xxxxxxxxxxxxxxxxxxxxxxxxxxx>

Hi, thanks.

Acked-by: Marek Vasut <marek.vasut@xxxxxxxxx>

> ---
> drivers/power/wm97xx_battery.c | 4 ++--
> 1 files changed, 2 insertions(+), 2 deletions(-)
>
> diff --git a/drivers/power/wm97xx_battery.c
> b/drivers/power/wm97xx_battery.c index 6ea3cb5..23eed35 100644
> --- a/drivers/power/wm97xx_battery.c
> +++ b/drivers/power/wm97xx_battery.c
> @@ -26,7 +26,7 @@
>
> static DEFINE_MUTEX(bat_lock);
> static struct work_struct bat_work;
> -struct mutex work_lock;
> +static struct mutex work_lock;
> static int bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
> static struct wm97xx_batt_info *gpdata;
> static enum power_supply_property *prop;
> @@ -203,7 +203,7 @@ static int __devinit wm97xx_bat_probe(struct
> platform_device *dev) goto err2;
> ret = request_irq(gpio_to_irq(pdata->charge_gpio),
> wm97xx_chrg_irq, IRQF_DISABLED,
> - "AC Detect", 0);
> + "AC Detect", dev);
> if (ret)
> goto err2;
> props++; /* POWER_SUPPLY_PROP_STATUS */
>
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/