[PATCH] hwmon: Add power meters to Documentation/hwmon/sysfs-interface

From: Darrick J. Wong
Date: Tue Aug 28 2007 - 12:45:11 EST


Update the hwmon sysfs interface documentation to include a specification
for power meters.

Signed-off-by: Darrick J. Wong <djwong@xxxxxxxxxx>
---

Documentation/hwmon/sysfs-interface | 15 +++++++++++++++
1 files changed, 15 insertions(+), 0 deletions(-)

diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface
index b3a9e1b..da546ce 100644
--- a/Documentation/hwmon/sysfs-interface
+++ b/Documentation/hwmon/sysfs-interface
@@ -304,6 +304,21 @@ curr[1-*]_input Current input value
Unit: milliampere
RO

+*********
+* Power *
+*********
+
+power[1-*]_input Current power use
+ Unit: milliWatt
+ RO
+
+power[1-*]_max_input Historical maximum power use
+ Unit: milliWatt
+ RO
+
+power[1-*]_min_input Historical minimum power use
+ Unit: milliWatt
+ RO

**********
* Alarms *