Re: [PATCH 00/23] per device dirty throttling -v8

From: Stewart Smith
Date: Mon Aug 13 2007 - 22:06:56 EST


On Mon, 2007-08-06 at 10:40 +0200, Brice Figureau wrote:
> Mysql accesses its database files in O_DIRECT mode.

binlog is written using buffered IO.

for InnoDB, binlog is synced first, then innodb log. on restart (in 5.0)
these are synced back up so you don't get inconsistencies.

and from a quick look at the innobase source, only data file is using
O_DIRECT.

> Since the database fits in RAM, the only kind of access Mysql is doing
> is writing to the innodb log, the mysql binlog and finally to the innodb
> database files.
> There are certainly a whole lot of fsync'ing happening.

yes. Keep in mind that the binlog grows in file size too... so this has
to sync all the metadata as well (ick, i know).
--
Stewart Smith, Senior Software Engineer
MySQL AB, www.mysql.com
Office: +14082136540 Ext: 6616
VoIP: 6616@xxxxxxxxxxxxxxxx
Mobile: +61 4 3 8844 332

Jumpstart your cluster:
http://www.mysql.com/consulting/packaged/cluster.html

Attachment: signature.asc
Description: This is a digitally signed message part