[RFC][PATCH] Change pcibus_to_cpumask() to pcibus_to_node()

From: Matthew Dobson
Date: Mon Jul 26 2004 - 19:13:11 EST


So in discussions with Jesse at OLS, we decided that pcibus_to_node() is
a more generally useful function than pcibus_to_cpumask(). If anyone
disagrees with that, now would be a good time to let us know.

This is just a preliminary patch. It needs review for x86_64, as I
don't know how to properly populate the mp_bus_to_node (which used to be
mp_bus_to_cpumask) array.

The main changes are as follows:

1) Replace instances of pcibus_to_cpumask(bus) with
node_to_cpumask(pcibus_to_node(bus)). There are currently only 2 uses
of pcibus_to_cpumask(): flush_gart() in arch/x86_64/kernel/pci-gart.c
and pci_bus_show_cpuaffinity() in drivers/pci/probe.c.
2) Define the asm-generic version of pcibus_to_node() to always return
node 0, as this is the sensible non-NUMA behavior.
3) Drop the mips/mach-ip27 and ppc64 versions of pcibus_to_cpumask()
entirely, since they were simply defined to be identical to the
asm-generic version.
4) Define the i386 version of pcibus_to_node().

Future work:

1) Correctly map PCI buses to nodes for x86_64.
2) IA64 implementation?
3) Other arch implementations?

[mcd@arrakis source]$ diffstat ~/linux/patches/pcibus_to_node.patch
arch/x86_64/kernel/mpparse.c | 3 ++-
arch/x86_64/kernel/pci-gart.c | 2 +-
drivers/pci/probe.c | 2 +-
include/asm-generic/topology.h | 4 ++--
include/asm-i386/topology.h | 4 ++--
include/asm-mips/mach-ip27/topology.h | 1 -
include/asm-ppc64/topology.h | 2 --
include/asm-x86_64/mpspec.h | 2 +-
include/asm-x86_64/topology.h | 6 ++----
9 files changed, 11 insertions(+), 15 deletions(-)

-Matt
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/arch/x86_64/kernel/mpparse.c linux-2.6.7-mm7+pcibus_to_node/arch/x86_64/kernel/mpparse.c
--- linux-2.6.7-mm7/arch/x86_64/kernel/mpparse.c 2004-07-12 10:39:11.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/arch/x86_64/kernel/mpparse.c 2004-07-26 15:09:30.000000000 -0700
@@ -44,7 +44,7 @@ int acpi_found_madt;
int apic_version [MAX_APICS];
unsigned char mp_bus_id_to_type [MAX_MP_BUSSES] = { [0 ... MAX_MP_BUSSES-1] = -1 };
int mp_bus_id_to_pci_bus [MAX_MP_BUSSES] = { [0 ... MAX_MP_BUSSES-1] = -1 };
-cpumask_t mp_bus_to_cpumask [MAX_MP_BUSSES] = { [0 ... MAX_MP_BUSSES-1] = CPU_MASK_ALL };
+int mp_bus_to_node [MAX_MP_BUSSES] = { [0 ... MAX_MP_BUSSES-1] = -1 };

int mp_current_pci_id = 0;
/* I/O APIC entries */
@@ -169,6 +169,7 @@ static void __init MP_bus_info (struct m
mp_bus_id_to_type[m->mpc_busid] = MP_BUS_PCI;
mp_bus_id_to_pci_bus[m->mpc_busid] = mp_current_pci_id;
mp_current_pci_id++;
+ /* FIXME: Setup PCI bus to Node mapping here? */
} else if (strncmp(str, "MCA", 3) == 0) {
mp_bus_id_to_type[m->mpc_busid] = MP_BUS_MCA;
} else {
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/arch/x86_64/kernel/pci-gart.c linux-2.6.7-mm7+pcibus_to_node/arch/x86_64/kernel/pci-gart.c
--- linux-2.6.7-mm7/arch/x86_64/kernel/pci-gart.c 2004-07-12 10:39:11.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/arch/x86_64/kernel/pci-gart.c 2004-07-26 15:12:55.000000000 -0700
@@ -148,7 +148,7 @@ static void flush_gart(struct pci_dev *d
{
unsigned long flags;
int bus = dev ? dev->bus->number : -1;
- cpumask_t bus_cpumask = pcibus_to_cpumask(bus);
+ cpumask_t bus_cpumask = node_to_cpumask(pcibus_to_node(bus));
int flushed = 0;
int i;

diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/drivers/pci/probe.c linux-2.6.7-mm7+pcibus_to_node/drivers/pci/probe.c
--- linux-2.6.7-mm7/drivers/pci/probe.c 2004-07-12 10:39:18.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/drivers/pci/probe.c 2004-07-23 07:49:24.000000000 -0700
@@ -54,7 +54,7 @@ postcore_initcall(pcibus_class_init);
*/
static ssize_t pci_bus_show_cpuaffinity(struct class_device *class_dev, char *buf)
{
- cpumask_t cpumask = pcibus_to_cpumask((to_pci_bus(class_dev))->number);
+ cpumask_t cpumask = node_to_cpumask(pcibus_to_node((to_pci_bus(class_dev))->number));
int ret;

ret = cpumask_scnprintf(buf, PAGE_SIZE, cpumask);
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/include/asm-generic/topology.h linux-2.6.7-mm7+pcibus_to_node/include/asm-generic/topology.h
--- linux-2.6.7-mm7/include/asm-generic/topology.h 2004-06-15 22:18:58.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/include/asm-generic/topology.h 2004-07-26 15:11:27.000000000 -0700
@@ -41,8 +41,8 @@
#ifndef node_to_first_cpu
#define node_to_first_cpu(node) (0)
#endif
-#ifndef pcibus_to_cpumask
-#define pcibus_to_cpumask(bus) (cpu_online_map)
+#ifndef pcibus_to_node
+#define pcibus_to_node(bus) (0)
#endif

/* Cross-node load balancing interval. */
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/include/asm-i386/topology.h linux-2.6.7-mm7+pcibus_to_node/include/asm-i386/topology.h
--- linux-2.6.7-mm7/include/asm-i386/topology.h 2004-06-15 22:19:01.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/include/asm-i386/topology.h 2004-07-23 07:56:16.000000000 -0700
@@ -61,9 +61,9 @@ static inline int node_to_first_cpu(int
}

/* Returns the number of the node containing PCI bus 'bus' */
-static inline cpumask_t pcibus_to_cpumask(int bus)
+static inline int pcibus_to_node(int bus)
{
- return node_to_cpumask(mp_bus_id_to_node[bus]);
+ return mp_bus_id_to_node[bus];
}

/* Node-to-Node distance */
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/include/asm-mips/mach-ip27/topology.h linux-2.6.7-mm7+pcibus_to_node/include/asm-mips/mach-ip27/topology.h
--- linux-2.6.7-mm7/include/asm-mips/mach-ip27/topology.h 2004-06-15 22:20:26.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/include/asm-mips/mach-ip27/topology.h 2004-07-23 07:54:20.000000000 -0700
@@ -7,7 +7,6 @@
#define parent_node(node) (node)
#define node_to_cpumask(node) (HUB_DATA(node)->h_cpus)
#define node_to_first_cpu(node) (first_cpu(node_to_cpumask(node)))
-#define pcibus_to_cpumask(bus) (cpu_online_map)

extern int node_distance(nasid_t nasid_a, nasid_t nasid_b);
#define node_distance(from, to) node_distance(from, to)
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/include/asm-ppc64/topology.h linux-2.6.7-mm7+pcibus_to_node/include/asm-ppc64/topology.h
--- linux-2.6.7-mm7/include/asm-ppc64/topology.h 2004-06-15 22:20:16.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/include/asm-ppc64/topology.h 2004-07-23 07:54:30.000000000 -0700
@@ -33,8 +33,6 @@ static inline int node_to_first_cpu(int
return first_cpu(tmp);
}

-#define pcibus_to_cpumask(bus) (cpu_online_map)
-
#define nr_cpus_node(node) (nr_cpus_in_node[node])

/* Cross-node load balancing interval. */
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/include/asm-x86_64/mpspec.h linux-2.6.7-mm7+pcibus_to_node/include/asm-x86_64/mpspec.h
--- linux-2.6.7-mm7/include/asm-x86_64/mpspec.h 2004-07-12 10:39:40.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/include/asm-x86_64/mpspec.h 2004-07-23 07:57:53.000000000 -0700
@@ -166,7 +166,7 @@ enum mp_bustype {
};
extern unsigned char mp_bus_id_to_type [MAX_MP_BUSSES];
extern int mp_bus_id_to_pci_bus [MAX_MP_BUSSES];
-extern cpumask_t mp_bus_to_cpumask [MAX_MP_BUSSES];
+extern cpumask_t mp_bus_to_node [MAX_MP_BUSSES];

extern unsigned int boot_cpu_physical_apicid;
extern int smp_found_config;
diff -Nurp --exclude-from=/home/mcd/.dontdiff linux-2.6.7-mm7/include/asm-x86_64/topology.h linux-2.6.7-mm7+pcibus_to_node/include/asm-x86_64/topology.h
--- linux-2.6.7-mm7/include/asm-x86_64/topology.h 2004-07-12 10:39:40.000000000 -0700
+++ linux-2.6.7-mm7+pcibus_to_node/include/asm-x86_64/topology.h 2004-07-23 07:59:29.000000000 -0700
@@ -20,11 +20,9 @@ extern cpumask_t node_to_cpumask[];
#define node_to_first_cpu(node) (__ffs(node_to_cpumask[node]))
#define node_to_cpumask(node) (node_to_cpumask[node])

-static inline cpumask_t pcibus_to_cpumask(int bus)
+static inline int pcibus_to_node(int bus)
{
- cpumask_t tmp;
- cpus_and(tmp, mp_bus_to_cpumask[bus], cpu_online_map);
- return tmp;
+ return mp_bus_to_node[bus];
}

#define NODE_BALANCE_RATE 30 /* CHECKME */