Re: i386 flags register clober in inline assembly

From: Jan Hubicka (jh@suse.cz)
Date: Sat Nov 17 2001 - 10:14:36 EST


>
> There are several inline assembly routines in the i386 port, which
> clobber the flags register, nevertheless fail to declare that.
> E.g. atomic_inc
>
> __asm__ __volatile__(
> LOCK "incl %0"
> :"=m" (v->counter)
> :"m" (v->counter));
>
> should be
>
> __asm__ __volatile__(
> LOCK "incl %0"
> :"=m" (v->counter)
> :"m" (v->counter)
> : "cc");
>
> since "incl" clobbers flags.
>
> Any ideas if these functions should be corrected ?
They don't need to be. On i386, the flags are (partly for historical reasons) clobbered
by default.
>
> Although gcc documentation says "cc" has no effect on some machines,
> it seems this is not the case with i386, judging from the "(set (reg:CC 17) ..."
> and "(clobber (reg:CC 17))" in i386.md.
i386.md does add the clobber to each asm statement.

Honza
>
> Regards,
> -velco
>
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/



This archive was generated by hypermail 2b29 : Fri Nov 23 2001 - 21:00:16 EST