Re: [PATCH v3 2/2] net: phy: dp83826: support TX data voltage tuning

From: POPESCU Catalin
Date: Fri Feb 09 2024 - 10:07:23 EST


On 09.02.24 15:07, Andrew Lunn wrote:
> [Some people who received this message don't often get email from andrew@xxxxxxx. Learn why this is important at https://aka.ms/LearnAboutSenderIdentification ]
>
> This email is not from Hexagon’s Office 365 instance. Please be careful while clicking links, opening attachments, or replying to this email.
>
>
> On Fri, Feb 09, 2024 at 01:36:28PM +0100, Catalin Popescu wrote:
>> DP83826 offers the possibility to tune the voltage of logical
>> levels of the MLT-3 encoded TX data. This is especially interesting
>> when the TX data path is lossy and we want to increase the voltage
>> levels to compensate the loss.
> Maybe i'm being nit-picky....
>
> "TX data path is lossy" should probably be "TX data path as far as the
> RJ46 socket is lossy". 802.3 probably defines the voltage at that
> point. If you tune it so the voltage is too high at that point, you
> are breaking the standard. So you can use this to adjust for losses in
> your coupling and cable run to the front panel. You should not be
> using this for range extension by cranking up the voltages. Yes, you
> might be able to, but we should not be encouraging it.

Indeed, the voltage drop (or loss) happens b/w the PHY and the connector
(could be RJ45, LEMO, etc).
Trying to reformulate :

DP83826 offers the possibility to tune the voltage of logical levels of
the MLT-3 encoded TX data. This is useful when there is a voltage drop
in between the PHY and the connector and we want to increase the voltage
levels to compensate for that drop.

Is this more meaningful ?

>
> Andrew